WeatherMaster® High-Efficiency Single Packaged Rooftop Units

Heat Pump with Puron® (R-410A) Refrigerant
3 to 10 Nominal Tons
WeatherMaster® 50HCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, “no-strip screw” collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally sound Puron (R-410A) refrigerant and are factory tested.
Performance Features
- ASHRAE 90.1 and Energy Star compliant
- Single-stage capacity control (sizes 04 to 07)
- Two-stage cooling capacity control (sizes 08 to 12)
- Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP
- Cooling operating range up to 125° F (52° C) and down to 30° F (-1° C) on size 04 to 14 units or down to 30° F (-1° C) on size 16 and 24 units
- Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
Maintenance Features
- Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
- Access panels with easy grip handles and tool-less filter access door
- Innovative, easy starting, no-strip screw feature on unit access panels
- Tool-less filter access door
- Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
- Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
- Two-inch disposable return air filters
Installation Features
- Same footprint as installed Carrier 3-10 ton rooftops back to 1989, reducing installation costs and time
- Field convertible from vertical to horizontal airflow for slab mounting (sizes 04 to 14)
- Provisions for thru-the-bottom power entry capability as standard
- Single point electric and control connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
Reliability Features
- Scroll compressors with internal line-break overload protection
- Compressor crankcase heaters (sizes 05 to 12)
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated evaporator-fan motor
- Totally enclosed condenser motors with permanently lubricated bearings
- Loss of charge, freeze protection, and high-pressure switches
- Dependable time/temperature defrost board and logic
Standard Limited Warranty
- 5-year parts only on electric heater
- 5-years parts only compressor
- 1-year parts only on other parts
- Extended warranty packages available
Factory-Installed Options
- Cabinet
- Thru-the-base electrical or gas-line connections
- Coil Options
- Cu/Cu indoor and/or outdoor coils
- Pre-coated outdoor coils
- Premium, E-coated outdoor coils
- Condenser Protection
- Condenser coil hail guard (louvered design)
- Controls
- PremierLink™ DDC communicating controller
- RTU OPEN™ open-protocol controller
- Smoke detector (supply and/or return air)
- Economizers & Outdoor
- EconoMi$er IV (for electro-mechanical controlled RTUs)
- EconoMi$er2 (for DDC controlled RTUs)
- Motorized 2 position outdoor-air damper
- Manual outdoor-air damper
- Barometric relief
- Power exhaust
- Economizer Sensors & IAQ Devices
- Single dry bulb temperature sensors
- Single enthalpy sensors
- Differential enthalpy sensor
- CO2 sensor (wall, duct, or unit mounted)
- Indoor Motor & Drive
- Multiple motor and drive packages
- Power Options
- Convenience outlet (powered)
- Convenience outlet (unpowered)
- Non-fused disconnect
Field-Installed Accessories
- Cabinet
- Thru-the-base electrical or gas-line connections
- Condenser Protection
- Condenser coil hail guard (louvered design)
- Controls
- Thermostats, temperature sensors, and subbases
- PremierLink™ DDC communicating controller
- Smoke detector (supply and/or return air) (sizes 17-30)
- Time Guard II compressor delay control circuit
- Filter status switch
- Fan status switch
- Economizers & Outdoor
- EconoMi$er IV (for electro-mechanical controlled RTUs)
- EconoMi$er2 (for DDC controlled RTUs)
- Motorized 2 position outdoor-air damper
- Manual outdoor-air damper
- Barometric relief
- Power exhaust
- Economizer Sensors & IAQ Devices
- Single dry bulb temperature sensors
- Differential dry bulb temperature sensors
- Single enthalpy sensors
- Differential enthalpy sensors
- CO2 sensor (wall, duct, or unit mounted)
- Low Ambient Control
- Motormaster® head pressure controller
- Roof Curbs
- Roof curb 14” (356mm)
- Roof curb 24” (610mm)